AUBRAUX
 

 

JitLab

Meas Definitions


 

Data Rise Time Definition


DspSee Symbol symbol measure data rise time


Active Edge Data Rise Time
Not Applicable It is the time difference from when a rising Data edge crosses the low threshold to when it crosses the high threshold.

Significance of statistics:
MeanNot important.
MinThe min rise time should be more than the specified limit. Too small a rise time will induce noise on adjacent signal lines.
MaxThe max rise time should be less than the specified limit. Too large a rise time will eat into the setup & hold times.
Peak cy-cyImportant. A higher cycle-to-cycle rise time indicates that the system is affected by noise or interference from adjacent signals or both.
Peak-to-peakNot important.


Previous | Next Jitter & Timing Measurement/Analysis Software
 
©Aubraux

All Rights
Reserved