AUBRAUX
 

 

JitLab

Meas Definitions


 

Data Fall Time Percent Definition


Active Edge Data Fall Time Percent
Not Applicable It is the time difference from when a falling Data edge crosses the high threshold to when it crosses the low threshold. The high and low thresholds are percentage of the levels of the Data period to which the falling edge belongs.

Significance of statistics:
MeanNot important.
MinThe min percent fall time should be more than the specified limit. To small a percent fall time will induce noise on adjacent signal lines.
MaxThe max percent fall time should be less than the specified limit. To large a percent fall time will eat into the setup & hold times.
Peak cy-cyImportant. A higher cycle-to-cycle percent fall time indicates that the system is affected by noise or interference from adjacent signals or both.
Peak-to-peakNot important.


Previous | Next Jitter & Timing Measurement/Analysis Software
 
©Aubraux

All Rights
Reserved