| Significance of statistics: |
| Mean | Not important. |
| Min | The min rise time should be more than the specified limit.
Too small a rise time will induce noise on adjacent signal lines. |
| Max | The max rise time should be less than the specified limit.
Too large a rise time will eat into the setup & hold times. |
| Peak cy-cy | Important. A higher cycle-to-cycle rise time indicates that the system is affected by
noise or interference from adjacent signals or both. |
| Peak-to-peak | Not important. |