AUBRAUX
 

 

JitLab

Meas Definitions


 

Clock Fall Slew Rate Definition


DspSee Symbol symbol measure clock fall slew rate


Active Edge Clock Fall Slew Rate
Not Applicable It is defined as clock high threshold - clock low threshold
clock fall time

Significance of statistics:
MeanNot important.
MinThe min fall slew rate should be more than the specified limit. Too large a fall slew rate will eat into the setup & hold times.
MaxThe max fall slew rate should be less than the specified limit. Too small a fall slew rate will induce noise on adjacent signal lines.
Peak cy-cyImportant. A higher cycle-to-cycle fall slew rate indicates that the system is affected by noise or interference from adjacent signals or both.
Peak-to-peakNot important.