Plot: Plot Module
The Plot module can display the inputs waveforms with respect to time.
It is designed to support unlimited waveforms, though more than 10 waveforms can make it cluttered.
It supports zoom operations, multiple cursors with position readout and auto-scrolling.
You can drag & drop min, max & cycle-cycle statistics from the stats window to the plot
window to center-on that particular statistic occurrence location.
It supports the programming and graphical user interface as explained below.
The Plot module supports following user interfaces:
Graphical Interface
Ports
CH1-4
Connect the waveform(s) to be viewed to the CHx input ports.
|
|
Schematic Symbol
|
Toolbar
Horizontal Cursors 
Click to show or hide horizontal cursors. You can drag a horizontal cursor with left mouse button to make precise
measurements on the horizontal axis. Pressing the left or right arrow on the keyboard moves cursor1 and doing so while
pressing Shift moves cursor2.
Vertical Cursors 
Click to show or hide vertical cursors. You can drag a vertical cursor with left mouse button to make precise
measurements on the vertical axis. Pressing the up or down arrow on the keyboard moves cursor1 and doing so while
pressing Shift moves cursor2.
Paired Cursors 
Click to show or hide paired cursors. Paired cursors are horizontal cursors with automatic vertical cursors. Moving
the horizontal cursors places the vertical cursors automatically at the current waveform value.
Color 
Click to change the color of the selected waveform.
ON/OFF 
Allows the selected waveform to be switched OFF without deleting it.
Wfm 
Enter a waveform number to select or click the up or down arrow to select a waveform.
Vertical Setup
Scale (Vertical) [Textbox]
Vertical scale is specified in volts per division. Enter a value either with keyboard or click the up or down arrow
to increase or decrease it. If Auto is checked, then the scale is automatically calculated to vertically fit the
waveform nicely in the plot window.
Offset (Vertical) [Textbox]
Vertical offset is specified in volts. Enter a value either with keyboard or click the up or down arrow to increase
or decrease it. If Auto is checked, then the offset is automatically calculated to vertically fit the waveform nicely in
the plot window.
Position (Vertical) [Textbox]
Vertical position is specified in divisions. Enter a value either with keyboard or click the up or down arrow to
increase or decrease it.
Horizontal Setup
Scale (Horizontal) [Textbox]
Horizontal scale is specified in seconds per division. Enter a value either with keyboard or click the up or down
arrow to increase or decrease it. If Auto is checked, then the scale is automatically calculated to horizontally fit the
waveform fully in the plot window.
Offset (Horizontal) [Textbox]
Horizontal offset is specified in seconds. Enter a value either with keyboard or click the up or down arrow to
increase or decrease it. If Auto is checked, then the offset is automatically calculated to horizontally fit the
waveform fully in the plot window.
Auto Scroll (Horizontal) [Checkbox]
If Auto Scroll is checked, and if Horizontal Offset up or down arrow is clicked, the offset automatically keeps on
increasing or decreasing respectively till one of the arrows is clicked again.
|